Skip to content

Features

Every capability, one building model

The same building model that computes your coverage also generates the network design, the power plan, the SOW, the proposal, and the as-built. Change the design, and everything downstream follows — from the first site walk to day-two operations.

02 · Design

Design every discipline on one model

Every discipline designs on the same building — the same walls, ceilings, and racks — so no engine works from a stale copy.

2D + 3D design studio

Place cameras, wireless APs, access control, conference AV, cabling, racks, and furniture from a real product library — in a live 2D canvas or full 3D scene.

Survey & design

Wi-Fi coverage

Plan AP placement and predict coverage with RF modeling that respects wall materials, then get remediation recommendations for the gaps.

ITU-R P.1238

Coverage physics

Camera coverage

Simulate camera fields of view and pixel density — with wall, glass, and racking occlusion — and generate POV reports and heatmaps.

DORI · IEC 62676-4

Coverage physics

Network design

Generate a tiered network topology with switch-port and patch-panel planning straight from the design.

Network design

Racks & MDF/IDF

Produce rack elevations and 3D MDF/IDF cabinet layouts that follow BICSI placement conventions.

BICSI

Network design

Structured cabling

Plan fiber and copper runs, and emit cable schedules and device labels to industry labeling standards.

BICSI · ANSI/TIA

Network design

Cable route optimization

Optimize cable routing and run lengths, and model pull tension before anyone pulls a cable.

Network design

PoE & electrical

Calculate PoE budgets, circuit and voltage-drop needs, and arc-flash.

IEEE 802.3 · NEC · IEEE 1584

Power & electrical

UPS & thermal

Size UPS runtime and rack heat load, and balance three-phase power.

Power & electrical

Conference AV

Assess rooms across display visibility, speech intelligibility, microphone pickup, and camera framing — per seat — with remediation.

AVIXA DISCAS · IEC 60268-16 STI

Conference AV

DAS, paging & sound masking

Design in-building cellular (DAS), paging, and sound masking on the same model.

NFPA 72

Coverage physics

Access control design

Doors, readers, locks, REX and controllers on the real plan — protocol-correct cable runs, controller capacity read from the datasheet, and UL 294 power sizing.

UL 294 · NFPA 101 · ADA

Access control design

Grounded intelligence

SOC never invents the numbers

The physics and cost engines own every figure — SOC researches, suggests, and explains, grounded in your own operational data with provenance and per-tenant limits.

See it on your own floor plans

Design on real floor plans, walk it in 3D, and prove the coverage — then hand off to the field. Talk to us about what your team needs.